OpenPlant Orthographics Manager Help

Outside - Distance

The Distance page provides options for you to define the distance for the dimension levels for external pipe, pipe elevation, equipment and structure.

Accessed by selecting the Outside > Distance node in the Settings interface.

Define the properties per the fields described below and Save the changes.

The Close icon closes the Project Settings interface, so make sure your changes are saved. You will be prompted to save them it you haven't already.

The Load Defaults icon in the main Settings interface will return the settings of the options page to their original values.

SettingDescription
Distance Parameters

A: The distance of the first level dimension, which are for the pipe, equipment and structure dimensions.

  • B: The distance of the second level dimension, which are equipment and structure dimensions.
  • C: The distance of the third level dimension, which is global dimension.
  • D: Reference the bitmap image to define the distance here.
  • E: Reference the bitmap image to define the distance here.
  • E1: If there are several elevation texts to point to other pipes in the nearby area, the leader lines of the elevation text should overlap. So there needs to be a gap distance defined among these leader lines. The default is 1 mm.
  • E2: The distance between the starting leader lines of the elevation text, which is the nearest leader line from the view frame. The default is 50 mm.
  • Gap A: Reference the bitmap image to define the distance here.
Labels

Pipe/Equipment: It is the distance of the label of the pipes or equipments.

Elevation: If the adjacent pipes outside the view have the same elevation, they can be grouped and be pointed by the elevation leader line as bottom of pipe/elevation text. Refer to the Tag Numbers > External View topic for additional information.

Structural: It is for the structure column annotation distance.